Industrial 4-Port Protocol Gateway, 10/100BASE-T(X) With PoE, Isolation
Product Description
The PG59XX Series is a highly reliable and fault tolerant Industrial Protocol Gateway. Its powerful architecture provides seamless conversion between the different protocols Ethernet or Serial based. The serial devices communicating on different protocols could be integrated into the system and extend its reach over the gateway’s redundant Ethernet. This device is designed to work in most demanding industries such as power substations, power generation, oil and gas, farming and manufacturing.
The configuration carried out through a use friendly, Java- Based Windows Utility called eNode Designer. It allows configuring target platforms, set device properties and protocol data point mapping. To do so, a project file representing the system should be created. This will include devices and the protocol applications running on them. The configuration is completely dependent on the “eNode Module” which represents that device or application – but may include things such as changing the communication port settings and defining where data point information enters and leaves the eNode Designer system.
PG59XX Series embeds an additional layer of security, allowing the devices to be deployed in topologies that request data to flow through the Internet and preventing sensitive control and monitoring data to be readable from malicious activities. IPsec VPN encryption, configurable in both peer-to-peer and peer-to-side modes will make sure the data passing is encrypted through a strong 128, 192 or 256-bit AES encryption.
Application
The protocol gateway’s embedded protocol stacks allow
– Seamless conversion
– Exception/error Management
– Unsolicited event management for the protocols requiring them (such as DNP3)
– High performance
– Low cost
The example shows how to Easily connect a Modbus Serial HMI, through ATOP’s Protocol Gateway to a IEC60870-5-101 Serial Slave RTU. The host HMI has the role of a Modbus Serial Master while the end-device to be accessed is a IEC60870-5-101 Serial Slave.
ATOP’s protocol Gateway acts towards the HMI seamlessly as a Modbus Serial Slave, answering the poll commands or the write commands required by the Host by its virtual Modbus ID. Meanwhile, it acts as a IEC60870-5-101 Serial Master, with regard to the end-device whose 101 address is mapped to the virtual Modbus ID that the HMI is accessing.
Be careful! – all gateway functions listed in the datasheet refer to the “Gateway” role, and not which “host” or “slave” the gateway is connected to. In this example, the SKU shown is “MBSS-01SM” (Modbus Serial Slave to IEC60870-5-101 Serial Master)
Speed | IEEE 802.3 10BaseT IEEE 802.3u 100BaseT(X) IEEE 802.3u for 100Base-X (SFP version only) IEEE 802.3z for 1000Base-X (SFP version only), USB 2.0 |
---|---|
PoE standard supported | |
LAN Mode | |
Connector ports | 2x 10/100BASE-T(X) RJ-45 or 2x 100/1000 Base-X SFP Slots (SFP version) |
Connector | 1×2 5 pin 3.81mm Terminal Block, or D-sub9 connector, 7-Pin 5.08mm Lockable Terminal Block, USB A Type |
Ports | |
Mode | |
Baud Rate | |
Parity | |
Data Bits | |
Stop Bits | |
Isolation | |
USB Ports | |
Protocols | |
Configuration | Atop Management Utility, Web UI, Telnet, Serial Console, ATOP eNode Designer |
Protocol setting | |
Supported Protocols | |
Protocol specifications | |
Input Voltage | Dual 12 – 48VDC (non-PoE Models); or through Ethernet Cable (PoE versions) |
Input Current (@ 12VDC) | |
Power Consumption | |
Power Redundancy | |
Reverse Polarity Protection | |
Relay Output | |
Housing | |
Dimension (W x H x D) | |
Weight | |
Installation | |
Reset Button | |
Operating Temperature | -40°C~85°C (-40°F~185°F) |
Storage Temperature | |
Ambient Relative Humidity |
We understand that it can be difficult to find the right products for your needs. That’s why our dedicated customer support team is available to assist you in any way possible. Whether you need help selecting the best product for your application or more information on a particular device, our knowledgeable staff is here to provide you with the answers you need. Contact us today for more information about how we can help you get the products and support you need!
Available on back-order
Available on back-order
Industrial 4-Port Protocol Gateway, 100/1000BASE-X with SFP Slot, Isolation
Available on back-order
Available on back-order
Available on back-order
Available on back-order
Available on back-order
Available on back-order
Available on back-order
Entry-level managed Ethernet switch with 8 10/100BaseT(X) ports, -10 to 60°C operating temperature
10 in stock (can be backordered)
Entry-level managed Ethernet switch with 8 10/100BaseT(X) ports, -10 to 60°C operating temperature, EtherNet/IP enabled
Available on back-order
Entry-level managed Ethernet switch with 6 10/100BaseT(X) ports, and 2 100BaseFX multi-mode ports with SC connectors, -10 to 60°C operating temperature
5 in stock (can be backordered)
Entry-level managed Ethernet switch with 6 10/100BaseT(X) ports, and 2 100BaseFX multi-mode ports with ST connectors, -10 to 60°C operating temperature
2 in stock (can be backordered)
Entry-level managed Ethernet switch with 8 10/100BaseT(X) ports, -10 to 60°C operating temperature, PROFINET enabled
Available on back-order
Entry-level managed Ethernet switch with 6 10/100BaseT(X) ports, and 2 100BaseFX single-mode ports with SC connectors, -10 to 60°C operating temperature
Available on back-order
Entry-level managed Ethernet switch with 8 10/100BaseT(X) ports, -40 to 75°C operating temperature, EtherNet/IP enabled
Available on back-order
Entry-level managed Ethernet switch with 6 10/100BaseT(X) ports, and 2 100BaseFX multi-mode ports with SC connectors, -40 to 75°C operating temperature
2 in stock (can be backordered)
Entry-level managed Ethernet switch with 6 10/100BaseT(X) ports, and 2 100BaseFX multi-mode ports with ST connectors, -40 to 75°C operating temperature
Available on back-order
Version | Name | Time | Size | Download |
---|---|---|---|---|
v1.29.011 | eNode designer – Caution: v1.27 and newer only support Protocol Gateway version 0.58 or newer | 2023-08-11 | 9.1 MB | Download |
v1.29 | eNode designer – Caution: v1.27 and newer only support Protocol Gateway version 0.58 or newer | 2023-04-19 | 8.87 MB | Download |
v1.28 | eNode designer – Caution: v1.27 and newer only support Protocol Gateway version 0.58 or newer | 2022-07-06 | 6.49 MB | Download |
v1.27 | eNode designer – Caution: v1.27 and newer only support Protocol Gateway version 0.58 or newer | 2021-04-16 | 6.49 MB | Download |
v1.0 | Tcpdump for diagnosis | 2021-03-29 | 1.22 MB | Download |
v5.60 | Management Utility for Windows | 2020-10-21 | 23.65 MB | Download |
v5.20 | Management Utility for Windows | 2016-10-28 | 16.21 MB | Download |
v1.26 | eNode Designer for Windows | 2020-05-11 | 6.45 MB | Download |
Version | Name | Time | Size | Download |
---|---|---|---|---|
v0.63 | PG59XX DNP3.0-Ethernet-Server-0.63 | 2023-07-12 | 138.67 MB | Download |
v0.63 | PG59XX DNP3.0-Serial-Slave-0.63 | 2023-07-12 | 138.67 MB | Download |
v0.63 | PG59XX IEC60870-5-101-Serial-Slave-0.63 | 2023-07-12 | 138.67 MB | Download |
v0.63 | PG59XX IEC60870-5-104-Ethernet-Server-0.63 | 2023-07-12 | 138.67 MB | Download |
v0.63 | PG59XX IEC61850-Ethernet-Server-0.63 | 2023-07-12 | 138.67 MB | Download |
v0.63 | PG59XX Modbus-RTU-ASCII-Serial-Slave-0.63 | 2023-07-12 | 118.86 MB | Download |
v0.63 | PG59XX Modbus-TCP-Ethernet-Server-v0.63 | 2023-07-12 | 118.86 MB | Download |
Version | Name | Time | Size | Download |
---|---|---|---|---|
v1.8 | Datasheet EN | 2023-11-01 | 178.46 KB | Download |
v1.5 | Datasheet EN | 2020-02-13 | 292.48 KB | Download |
v1.4 | Datasheet EN | 2019-12-25 | 290.39 KB | Download |
v1.3 | Datasheet EN | 2018-05-18 | 293.72 KB | Download |
v1.2 | Datasheet EN | 2018-03-20 | 699.37 KB | Download |
Version | Name | Time | Size | Download |
---|---|---|---|---|
v1.5 | eNode Designer User Manual DNP3.0 | 2023-08-11 | 5.47 MB | Download |
v1.6 | eNode Designer User Manual IEC 61850 | 2023-08-11 | 948.18 KB | Download |
v1.4 | eNode Designer User Manual IEC60870-5-101/104 | 2023-08-11 | 2.72 MB | Download |
v1.5 | eNode Designer User Manual IEC60870-5-103 | 2023-08-11 | 1.19 MB | Download |
v1.5 | eNode Designer User Manual Modbus | 2023-08-11 | 1.24 MB | Download |
v1.7 | Getting started with Atop PG and eNode Designer | 2023-08-11 | 3.01 MB | Download |
© 2023 IT4 Automation Ltd. All Rights Reserved