Supported Documents
Name | Type | Version | Release Date |
---|---|---|---|
|
QIG | v1.3 |
May 18, 2023 |
|
Manual | v2.1 |
Mar 28, 2023 |
|
Tech Note | v2.1 |
Jan 13, 2022 |
|
Manual | v1.1 |
Aug 30, 2019 |
Available on back-order
1-port Modbus/PROFINET/EtherNet/IP to PROFIBUS slave gateway, 0 to 60°C operating temperature
MGate 5111 industrial Ethernet gateways convert data from Modbus RTU/ASCII/TCP, EtherNet/IP, or PROFINET to PROFIBUS protocols. All models are protected by a rugged metal housing, are DIN-rail mountable, and offer built-in serial isolation.
Modbus is one of the most widely used industrial communication protocols, and EtherNet/IP, PROFINET, and PROFIBUS are commonly used in factory automation and process automation. The MGate 5111 supports both Modbus RTU/ASCII/TCP master and slave modes, so that you can easily connect your Modbus device to PROFIBUS PLCs or DCSs, such as Siemens PLCs. For system integration, the MGate 5111 can connect to EtherNet/IP PLC/SCADA systems, such as Rockwell Automation PLCs, to PROFIBUS PLC/DCS systems, or between a new Siemens PLC system that supports PROFINET to an existing PROFIBUS system.
The MGate 5111 gateways are designed for easy configuration and quick maintenance. A handy web console can be used to implement remote maintenance tasks, and the configuration wizard UI lets you quickly set up your gateway. A comprehensive collection of troubleshooting tools reduce configuration time and system downtime. The rugged design is suitable for industrial applications, such as factory automation, power, oil and gas, water and wastewater, and other process automation industries.
The MGate 5111 Series has a user-friendly interface that lets you quickly set up protocol conversion routines for most applications, doing away with what were often time-consuming tasks in which users had to implement detailed parameter configurations one by one. With Quick Setup, you can easily access protocol conversion modes and finish the configuration in a few steps.
The MGate 5111 supports a web console and Telnet console for remote maintenance. Encryption communication functions, including HTTPS and SSH, are supported to provide better network security. In addition, system monitoring functions are provided to record network connections and system log events.
The MGate 5111 supports Protocol Diagnose and Traffic Monitor for easy troubleshooting, especially during the installation stage. Communication issues caused by incorrect software parameters, such as slave IDs and register addresses, or incorrect command configurations, can be fished out with Protocol Diagnose and Traffic Monitoring, which let you capture and check data to easily identify root causes.
MGate 5111 gateways also support status monitoring and fault protection functions. The status monitoring function notifies a PLC/DCS/SCADA system when a Modbus device gets disconnected or does not respond, in which case the process PLC/DCS gets the status of each end device and then issues alarms to notify operators. When a PROFIBUS cable gets disconnected, the fault protection function executes actions on end devices identified by a predefined value set by the user.
Management | |
---|---|
Console Port | |
RS-232 | |
Configuration Options | |
Functions Supported | |
Max. No. of Client Connections | |
Max. No. of Server Connections | |
Max. No. of Commands | |
RS-485 Data Direction Control | |
Terminator for RS-485 | |
Industrial Protocols | |
No. of Ports | |
Connector | |
Isolation | |
Rotary Switch | PROFIBUS addresses 0-99 (addresses 100-125 supported through software configuration) |
Mode | |
CIP Objects Supported | Identity, Message Router, Assembly, Connection Manager, TCP/IP interface, Ethernet link, Port |
Input Data Size | |
Output Data Size | |
microSD Slot | |
Contact Current Rating | |
Input Voltage | |
Input Current | |
Power Connector | |
Housing | |
IP Rating | |
Dimensions | |
Weight | |
Ambient Relative Humidity | |
Operating Temperature | 0 to 60°C (32 to 140°F) |
Safety | |
EMC |
We understand that it can be difficult to find the right products for your needs. That’s why our dedicated customer support team is available to assist you in any way possible. Whether you need help selecting the best product for your application or more information on a particular device, our knowledgeable staff is here to provide you with the answers you need. Contact us today for more information about how we can help you get the products and support you need!
1-port Modbus/PROFINET/EtherNet/IP to PROFIBUS slave gateway, 0 to 60°C operating temperature
Available on back-order
Available on back-order
Entry-level managed Ethernet switch with 8 10/100BaseT(X) ports, -10 to 60°C operating temperature
10 in stock (can be backordered)
Entry-level managed Ethernet switch with 8 10/100BaseT(X) ports, -10 to 60°C operating temperature, EtherNet/IP enabled
Available on back-order
Entry-level managed Ethernet switch with 6 10/100BaseT(X) ports, and 2 100BaseFX multi-mode ports with SC connectors, -10 to 60°C operating temperature
5 in stock (can be backordered)
Entry-level managed Ethernet switch with 6 10/100BaseT(X) ports, and 2 100BaseFX multi-mode ports with ST connectors, -10 to 60°C operating temperature
2 in stock (can be backordered)
Entry-level managed Ethernet switch with 8 10/100BaseT(X) ports, -10 to 60°C operating temperature, PROFINET enabled
Available on back-order
Entry-level managed Ethernet switch with 6 10/100BaseT(X) ports, and 2 100BaseFX single-mode ports with SC connectors, -10 to 60°C operating temperature
Available on back-order
Entry-level managed Ethernet switch with 8 10/100BaseT(X) ports, -40 to 75°C operating temperature, EtherNet/IP enabled
Available on back-order
Entry-level managed Ethernet switch with 6 10/100BaseT(X) ports, and 2 100BaseFX multi-mode ports with SC connectors, -40 to 75°C operating temperature
Available on back-order
Entry-level managed Ethernet switch with 6 10/100BaseT(X) ports, and 2 100BaseFX multi-mode ports with ST connectors, -40 to 75°C operating temperature
Available on back-order
Name | Type | Version | Operating System | Release Date | |
---|---|---|---|---|---|
|
Utility |
DC896CA58822B47BB2C85B25D4F391E82BCC8890522C7C4A8407D6AB07943693364883E44A389792B419B0B8CF125BE19E0D71F0144074F00CE859110D308977 SHA-512 |
v1.3 |
Show More
|
Jun 29, 2023 Jun 29, 2023 Release notes |
|
Utility |
A4A6137B7B59DFA30231958FF83FE4D15315B6D06935E892112CE7252F5E0E163D72A1D24D1ADE48F107A0A5E138A2AF569BE0EBF1331261B061DA1904A7BD47 SHA-512 |
v1.3 |
Show More
|
Jun 29, 2023 Jun 29, 2023 Release notes |
|
Utility |
9F3E3C6A2BBDCBFC53A91CAA82372972B0A9888CB75C1F9F8E32324F50FF8A0FF7500417AB873469B00AE8C20EE6C0D0C8C50CB94BFC3517AE604879244440FD SHA-512 |
v2.7 |
Show More
|
Jun 28, 2023 Jun 28, 2023 Release notes |
|
Firmware |
488F26321B42C6417A63B1CF1C12DCCF6FFFC0BA07B574C7DA129E8EA76C6DCC29AABD0D318E686D470D8871AB387ACBC27237498EC5CFFEEE935FE5EE61DEAB SHA-512 |
v2.0 |
|
May 31, 2023 May 31, 2023 Release notes |
|
Software Package |
BC3C2EF37445EED1E65F1912C7344433F7A79268C1AE85EC75CCCEC77A8235136124639515E15DBE6240E592A5A2954F3A5D501E52B89DEA007654254705C62C SHA-512 |
v1.1.0 |
Show More
|
Feb 08, 2023 Feb 08, 2023 Release notes |
|
Software Package |
BE1C57655A0C398122DA1BB48984E0751203A262B51EAB83F91C06F0B2FAA0DFA71D5F311CE83CCA6E6FAE6C807EB69652281F199DA48132DF8048001AC5151D SHA-512 |
v3.2.8 |
Show More
|
Oct 31, 2022 Oct 31, 2022 Release notes |
|
Firmware |
8847483260664163BFB48C20BE599FC21CAC09A4F15869FE6EF62D4602AEF4719AB06AB08F0BF9D4995FA4F6CF852F59EC536E13F9C601C071CD43016BE37416 SHA-512 |
v1.4 |
|
Apr 29, 2022 Apr 29, 2022 Release notes |
|
Software Package |
92839A279E440C9663304019291349B60D99D06B9B5DB5AF0A12D6AEA9571FC391E829B585686A44CDC036A29BA9FD46C923476DC3A5F45FE249AA1B4381C3E6 SHA-512 |
v1.1 |
Show More
|
Mar 31, 2021 Mar 31, 2021 Release notes |
|
Software Package |
C1B5A4F50BBFEB619F069639AA3AF41A9285533AF974E35BDB9025F81B8B95D37DBB3DBED4024F03523DF06EE58E596340C5437906214CF14487B2B1DAC86A51 SHA-512 |
v1.1 |
Show More
|
Mar 31, 2021 Mar 31, 2021 Release notes |
|
Software Package |
EEC30465FA5C11919FB455BEB365B44F169139E03A1F96CA37664AF95634ACF7EE30E0BBA8FDEFEAE7D3F90370697E4ADC696D38AE1A24634797BA080DF925C8 SHA-512 |
v2.1 |
|
Sep 02, 2019 Sep 02, 2019 Release notes |
|
Software Package |
57BC12FDCB65A6631E4225E0B8C73F3D1030E55DA52CEFDD8600E941EE80195D6FE76B6D1A226AD97AAAB2BC770B662B071B9B1EA0FB11F9F285033FBE767304 SHA-512 |
v1.0 |
|
Jan 19, 2018 Jan 19, 2018 Release notes |
|
Software Package |
F5E00B8F1E27C5D045F3717E8242973298063E43DBDA6B9ABD6D01B7FEB16FEDE1199CBBEC6BF76F8F6DC7F77C6199FEC2A1D2D6E317BDCE638F0CA352A7E891 SHA-512 |
v1.0 |
|
Jan 18, 2018 Jan 18, 2018 Release notes |
|
Software Package |
49AE89801CA017C6895650DFCDC7520A5A1AFE2D8895BE9C92EEE397060DEC3FD435605A087936F92D12C97476863BBBFCCD676FC71B3751F972694BBBF321A9 SHA-512 |
v1.0 |
|
Jan 18, 2018 Jan 18, 2018 Release notes |
Name | Type | Version | Release Date |
---|---|---|---|
|
QIG | v1.3 |
May 18, 2023 May 18, 2023 |
|
Manual | v2.1 |
Mar 28, 2023 Mar 28, 2023 |
|
Tech Note | v2.1 |
Jan 13, 2022 Jan 13, 2022 |
|
Manual | v1.1 |
Aug 30, 2019 Aug 30, 2019 |
|
Datasheet | v1.0 |
Nov 12, 2018 Nov 12, 2018 |
|
Tech Note | v1.0 |
Dec 28, 2017 Dec 28, 2017 |
|
2D CAD | Â | Dec 22, 2017 Dec 22, 2017 |
© 2023 IT4 Automation Ltd. All Rights Reserved