S
Supported Documents
Name | Type | Version | Release Date |
---|---|---|---|
|
Datasheet | v1.6 |
May 15, 2023 |
|
Manual | v1.6 |
Jul 25, 2022 |
|
QIG | v1.2 |
Sep 01, 2021 |
|
Manual | v1.2 |
Feb 25, 2021 |
Available on back-order
1G CPU module, C/C++ programmable controller, M12, -40 to 75°C
The ioPAC 8600 Series modular programmable controllers are 100% modular, giving you the freedom to choose the power, backplane, communication, and I/O modules you need for your application. In addition, the ioPAC 8600 enhances the hardware system architecture and key features of the ioPAC 8020 and ioPAC 8500 combined, and has an Ethernet bus on the backplane to support Ethernet switch modules.
The ioPAC 8600 supports the C/C++ and IEC 61131-3Â programming languages and ready-to-run services, including Modbus TCP/RTU, SNMP, data logging, and email alarms to fulfill different customer requirements. With active tag and MX-AOPC UA Suite data integration software, the ioPAC 8600 Series provides a comprehensive solution for data acquisition and control applications in harsh environments.
Moxa’s ioPAC 8600-CPU30 module is equipped with a new 1GHz high-performance Cortex™ A8 CPU, which shortens the cycle time significantly, and allows users to run more programs simultaneously. With the CPU30 module’s 4 GB eMMC, the ioPAC 8600 can support more communication protocols for a wider range of scenarios. The CPU30 also reserves up to 1.7GB of internal storage that gives users the freedom to develop more complex programs for specific ioPAC applications. As an added bonus, users can develop programs directly on the ioPAC.
Additional customization is required.
Moxa’s ioPAC 8600 programmable controllers use a tag-centric design with ready-to-run services. The tag-centric design helps streamline the connection between the ioPAC 8600 controller and remote I/Os, and allows you to easily manage I/O status by implementing get/set routines to read-from/write-to tag values, even if you are not particularly familiar with PLC FBDs and APIs. The ready-to-run service allows programmers to rapidly configure services (SNMP, Modbus RTU/TCP, email alarms, etc.) without writing a single line of code, reducing the development of complicated communication applications to a few mouse clicks. The ioPAC 8600’s tag-centric design and ready-to-run service greatly increase an engineer’s productivity.
Moxa’s 2-wire Ethernet technology offers system integrators an attractive option for upgrading a train’s IP network to a 10/100 Mbps
When using 2-wire technology, network performance is dependent on cable quality.
Ethernet backbone with existing 2-wire cable. This innovative technology greatly reduces cable usage by providing 100 Mbps Ethernet transmission over only two wires, thereby reducing the train’s weight and improving energy efficiency. The 2-wire Ethernet switch module supports Ethernet bypass functionality, ensuring that the Ethernet backbone will continue to operate even if one ioPAC unit is without power. As an added bonus, by installing two 2-wire Ethernet modules in one ioPAC unit, the network can transmit at 200 Mbps and provide a redundant architecture.
The compact ioPAC 8600 programmable controller is well-suited for smaller sized installation spaces, and its lightweight design reduces energy consumption and allows the product to withstand the wear and tear of railway applications. However, the ioPAC’s small size does not limit its capabilities. The ioPAC 8600 is equipped with universal dual power inputs that support all railway power voltages. With support for both 85M and 86M modules, the ioPAC 8600 programmable controller can implement the wide variety of IO scenarios required by train applications. The ioPAC 8600 also supports a variety of communication interfaces, including Ethernet, serial, CAN, and HART.
HART only available on a project basis.
System integrators can control or monitor subsystems with the ioPAC 8600, which saves space and provides powerful functions that both fit within the system integrator’s budget and overcome installation difficulties.
CPU | |
---|---|
eMMC | |
SDRAM | |
SPI-NVRAM | |
Language | |
Configuration Options | |
Industrial Protocols | |
Management | |
Authentication | |
Encryption | |
Security Protocols | |
Console Port | |
Functions Supported | |
Mode | |
Power Consumption | |
Operating Temperature | -40 to 75°C (-40 to 167°F) |
Ambient Relative Humidity | |
Altitude | |
EMC | |
EMI | |
Railway | |
Time | |
Standards | |
Housing | |
Weight | |
Warranty Period | |
Details |
We understand that it can be difficult to find the right products for your needs. That’s why our dedicated customer support team is available to assist you in any way possible. Whether you need help selecting the best product for your application or more information on a particular device, our knowledgeable staff is here to provide you with the answers you need. Contact us today for more information about how we can help you get the products and support you need!
Available on back-order
Power module, dual power input, 24-110 VDC, 15W, -40 to 75°C
Available on back-order
1G CPU module, IEC 61131-3 programmable controller, RJ45, -40 to 75°C
Available on back-order
1G CPU module, IEC 61131-3 programmable controller, M12, -40 to 75°C
Available on back-order
Available on back-order
ioPAC 8600 backplane modules with 12 I/O slots, -40 to 75°C operating temperature
Available on back-order
Available on back-order
Available on back-order
Available on back-order
Available on back-order
Available on back-order
Available on back-order
Available on back-order
Available on back-order
Available on back-order
Available on back-order
Name | Type | Version | Operating System | Release Date | |
---|---|---|---|---|---|
|
Firmware |
35493BAD38055D65583A1C2E14A2AE90E1AB2A0CBFEA87A8CA3F4CC9BB9642074452F5496C467779EB396890AA9A717F7755F90D02D809C1950BD7A6C3D82A8A SHA-512 |
v2.0 |
|
Apr 21, 2023 Apr 21, 2023 Release notes |
|
Utility |
2E501F77946C2C9083C788E3F8AB7987ABD260FD28F3542E6F6909C6049545F530096B096B514AE31C36BDF425B723DB450ACA523099B098CC838FA313219E9B SHA-512 |
v2.2 |
Show More
|
Nov 28, 2022 Nov 28, 2022 Release notes |
|
Utility |
5A6105F1FEF721CA0B57945F1C0317B0638B83F7F926F8B3234FB071700521A7956DD7B09037DD79E313AB8B2DF52F4035324CB70D53751CC707A2D717461EC6 SHA-512 |
v2.2 |
Show More
|
Nov 28, 2022 Nov 28, 2022 Release notes |
|
Utility |
43CE035465AA7DAF2A5E0DB246AC9D32CDADB00111AC9F761FB74A5ACE2452B5AE2B18692C4ED76848C4807A40B0B95EEECF3868A05747D8FB593FEF5B31C3B9 SHA-512 |
v1.9 |
Show More
|
Aug 23, 2022 Aug 23, 2022 Release notes |
|
Software Package |
C0CCF1604A95016F48074901BCE9B9E8F7A0941975F6FAB896B7CF30F2B23E44EE26261E896C7D754D3166BD3D2A501CBD3958934ECFC0A7C281C0BA8CC42A8E SHA-512 |
v1.1 |
|
Jun 05, 2020 Jun 05, 2020 Release notes |
|
Firmware |
6C879FC13EFB0B4D4673157E9B4F4D237D6499B9720C7EC64AD9836149A48BE62C77DBEC89F637FF6095BFBD7F2F11C0BE9C7B43E3C1FD0C11A314026AC8E76D SHA-512 |
v1.2 |
|
Jun 05, 2020 Jun 05, 2020 Release notes |
|
Utility |
31622C5AB7684BE0AFE116D8A79CA9247026E9E4434057F4FF08CF2E85AA94B29CA781097102D384EEC1BDB9198C38BF3FB85B065DFCFD229E81E0638A0BFDCF SHA-512 |
v2.1 |
Show More
|
May 16, 2019 May 16, 2019 Release notes |
|
Utility |
AC1FD18169FC6381EBCD04A190FEDD2F80D1AE5A5766C5595A5FF2CF7B770D108087EBD526C37F8E7B68FFA4809162A37985EF9BA4B0F687804A71B9FAB1AD5D SHA-512 |
v2.1 |
Show More
|
May 16, 2019 May 16, 2019 Release notes |
|
Software Package |
807D3C027F0254A5AFFCC0E3C558B7172548B8ED42AC3191FDB13495E7AFD6782ADE50B49901BA03736B71BED5323A41A9D94C0BC5386E2DF6B8E72637977C7F SHA-512 |
v1.0.0 |
|
Jan 17, 2019 Jan 17, 2019 Release notes |
|
Software Package |
65AB2718CE2ED162B7EAC5DAA9D8D81DB5B76083E22D03CD2B0324C118A09E2B2D76D2438498D78438DAC91AF7A0745BF89AD59F76B8B2AEF41F36737207BC3F SHA-512 |
v1.1.0 |
|
Jun 28, 2017 Jun 28, 2017 Release notes |
Name | Type | Version | Release Date |
---|---|---|---|
|
Datasheet | v1.6 |
May 15, 2023 May 15, 2023 |
|
Manual | v1.6 |
Jul 25, 2022 Jul 25, 2022 |
|
QIG | v1.2 |
Sep 01, 2021 Sep 01, 2021 |
|
Manual | v1.2 |
Feb 25, 2021 Feb 25, 2021 |
|
2D CAD | Â | Mar 05, 2018 Mar 05, 2018 |
|
2D CAD | Â | Jun 01, 2017 Jun 01, 2017 |
|
2D CAD | Â | Jun 01, 2017 Jun 01, 2017 |
|
2D CAD | Â | Jun 01, 2017 Jun 01, 2017 |
|
2D CAD | Â | Jun 01, 2017 Jun 01, 2017 |
|
2D CAD | Â | Jun 01, 2017 Jun 01, 2017 |
|
2D CAD | Â | Nov 24, 2016 Nov 24, 2016 |
|
2D CAD | Â | Jun 25, 2015 Jun 25, 2015 |
|
2D CAD | Â | Jun 25, 2015 Jun 25, 2015 |
|
2D CAD | Â | Jun 25, 2015 Jun 25, 2015 |
|
2D CAD | Â | Jun 25, 2015 Jun 25, 2015 |
|
Manual | v1.0 |
Apr 03, 2014 Apr 03, 2014 |
© 2023 IT4 Automation Ltd. All Rights Reserved