DA-720-C5-DPP

0 products currently in stock. Call our team for lead times if needed.

£4,244.00

Intel® 6th Gen Core™ processor, IEC-61850, 2U rackmount computers with 3 PCIe expansion slots

DA-720-C5-DPP

£4,244.00

Core i5-6300U, 2.4 GHz, Dual Core CPU, without mSATA/RAM/OS, dual power, -25 to 55°C temp, IEC 61850-3 compliant.

EN50121-certification-logo-image
fcc-certification-logo-image
iec61850-3-ieee1613-black-certification-logo-image
Series Description

Introduction

The DA-720 Series computers are x86 platforms with 14 Gigabit Ethernet ports, 2 isolated RS-232/422/485 serial ports, USB, VGA, and 3 PCIe ports for expansion modules. The DA-720 comes in a standard 19-inch 2U rack-mountable case with a robust design ideal for specialized industrial automation applications, including power substations, transportation and shipping, and oil and gas production and supply.

With IEC-61850-3 and IEEE 1613 compliance, the DA-720 is sure to deliver stable and reliable system operation for power applications. The DA-720 also complies with the IEC 60255 standards, which cover the protection of electrical relays in a smart substation. IEC 60255 is one of the most widely used standards for testing relays and protection equipment, and compliance with the standard ensures that the DA-720 will work reliably and seamlessly with IEDs as part of a robust substation automation system.

EN 50121-4 compliance confirms that the DA-720 can deliver stable and reliable system operations in rail wayside applications, such as station SCADA systems, wayside disaster prevention, traction power, and signaling and safety systems to provide an integrated view of your smart rail setup.

The DA-720 comes with two different CPU options and basic models that allow system designers to install the mSATA, RAM, and operating system according to their specific requirements. Such a wide choice of options is particularly welcome when it comes to designing customized industrial solutions.

The DA-720 comes with 3 PCIe ports for expansion modules, including an 8-port RS-232/422/485 module, 4-port and 8-port 10/100/1000 Mbps LAN modules, a 2-port 100/1000 Mbps PCIe PRP/HSR LAN module, a dual 2.5” SATA III SSD/HDD socket module, and a 2-port IRIG-B time-synchronization module with a 4 DI/DO module. The DA-720 computers can support up to 22 Gigabit LAN ports plus 16 serial ports, or 14 Gigabit LAN ports and 24 serial ports, making the DA-720 an ideal solution for a wide range of industrial automation applications.

The PRP-HSR expansion module is compliant with IEC 62439-3 Clause 4 (PRP) and IEC 62439-3 Clause 5 (HSR) to ensure the highest system availability and data integrity for mission-critical applications that require redundancy and zero-time recovery. With dual Gigabit Ethernet port design, the DE-PRP-HSR-EF provides high performance for redundant network systems. Moxa’s DA-720 Series industrial computer with the DE-PRP-HSR-EF is the ideal solution for power substation automation and process automation systems.

Smart Recovery Function

The DA-720’s Smart Recovery function minimizes downtime by making it easy to recover from operating system crashes. Engineers who are experts in a particular vertical market may not have enough computer domain knowledge to know how to fix operating system problems. Moxa Smart Recovery™ is an automated BIOS-level software recovery system that allows engineers to automatically trigger OS recovery to minimize downtime.

Proactive Monitoring Function

Moxa Proactive Monitoring is a small-footprint, resource-friendly, easy-to-use utility available with some Moxa computers to track a number of system parameters. You can view the current values for key parts by simply clicking on the icons corresponding to the parameters in a Windows-based user interface. User-defined key part indicators (KPIs) are used to monitor the computer’s key parts. Visible and/or audio alerts are triggered automatically via relays and SNMP traps when these KPIs exceed their preset threshold values, making it extremely convenient for operators to avoid system downtime by setting up predictive maintenance tasks well in advance.

The Proactive Monitoring tool is currently available with the following:DA-820C SeriesDA-720 SeriesMC-1200 SeriesMC-7400 Series

Appearance

Front View

Rear View

Need Support?

We understand that it can be difficult to find the right products for your needs. That’s why our dedicated customer support team is available to assist you in any way possible. Whether you need help selecting the best product for your application or more information on a particular device, our knowledgeable staff is here to provide you with the answers you need. Contact us today for more information about how we can help you get the products and support you need!

Product Brand

Moxa is a leading provider of edge connectivity, industrial computing, and network infrastructure solutions for enabling connectivity for the Industrial Internet of Things (IIoT). With over 35 years of experience, they help industrial enterprises overcome roadblocks and achieve operational resilience through purpose-built OT networking and cybersecurity. They are dedicated to changing the world through the power of connectivity, driving industrial transformation.

DA-720 Series

A series refers to a collection of related products or components designed to work together seamlessly, typically within a specific industry or application. These series often share similar features and functionalities, ensuring compatibility and ease of integration for users.
No data was found

Software, Firmware, and Drivers

NAME TYPE CHECKSUM VERSION OPERATING SYSTEM RELEASE DATE
Software Package for MXview One Series (Windows version)

277.4 MB

Software Package
SHA-512
v1.1.0
  • Windows 10
  • Windows 11
  • Windows Server 2016

Feb 08, 2023Release notes
Software Package for MXview One Series (Linux version)

251.0 MB

Software Package
SHA-512
v1.1.0
  • Linux
Feb 01, 2023Release notes
x86 Computers (Linux drivers and SDK)

802.0 bytes

Software Package
SHA-512
v1.1
  • CentOS 7.9
  • Debian 11.x
  • Ubuntu 20.04
Nov 28, 2022Release notes
MXview

417.7 MB

Software Package
SHA-512
v3.2.8
  • Windows 10
  • Windows 7
  • Windows Server 2012 R2

Oct 31, 2022Release notes
Proactive Monitoring Software Package (Windows edition)

68.4 MB

Software Package
SHA-512
v2.2
  • Windows 10
Aug 02, 2021Release notes
Driver for DA-720 Series (Perpheral for Linux)

1.3 MB

Driver
SHA-512
v1.0
  • Debian 8.x
May 25, 2017Release notes
Driver for DA-720 Series (Expansion Module for Windows 10)

226.1 MB

Driver
SHA-512
v1.0
  • Windows 10 Enterprise LTSB
May 25, 2017Release notes
Firmware for DA-720 Series (Linux)

629.4 MB

Firmware
SHA-512
v1.0
  • Debian 8.x
May 25, 2017Release notes
Driver for DA-720 Series (Perpheral for Windows 10)

897.3 MB

Driver
SHA-512
v1.1
  • Windows 10 Enterprise LTSB
May 25, 2017Release notes
Library for DA-720 Series (Example for Windows 10)

39.4 MB

Library
SHA-512
v1.0
  • Windows 10 Enterprise LTSB
May 25, 2017Release notes
Utility for DA-720 Series (DEB_KEY for Linux)

1.6 KB

Utility
SHA-512
v1.0
  • Debian 8.x
May 25, 2017Release notes
Utility for DA-720 Series (SerialInterface for Windows 10)

495.1 KB

Utility
SHA-512
v1.0
  • Windows 10 Enterprise LTSB
May 25, 2017Release notes
Utility for DA-720 Series (setinterface for Linux)

5.6 KB

Utility
SHA-512
v1.0
  • Debian 8.x
May 25, 2017Release notes
Utility for DA-720 Series (SmartRecovery for Windows 10)

184.3 MB

Utility
SHA-512
v1.0
  • Windows 10 Enterprise LTSB
May 25, 2017Release notes
Utility for DA-720 Series (Proactive Monitoring for Windows 7)

8.1 MB

Utility
SHA-512
v1.5
  • Windows 7
Apr 17, 2017Release notes

Support Documents

NAME TYPE VERSION RELEASE DATE
Datasheet for DA-720 Series

1.5 MB

Datasheet v1.6 Feb 22, 2023
Windows 10 IoT Enterprise LTSC 2021 (212H) User Manual for x86 Computers

9.4 MB

Manual v1.2 Jan 20, 2023
Manual for DA-720 Series (Windows)

4.3 MB

Manual v3.0 Dec 16, 2022
Manual for DA-720 Series (hardware)

10.5 MB

Manual v3.2 Sep 28, 2022
QIG for DA-720 Series

674.5 KB

QIG v1.2 Sep 07, 2022
Compatibility Guide for DA-720 Series

617.5 KB

Compatibility Guide v2.2 Feb 19, 2019
Manual for DA-720 Series (Linux)

1.8 MB

Manual v2.0 Mar 30, 2018
Supported Documents & Firmware Last Updated: February 6, 2023