Introduction
The ioLogik R1200 Series RS-485 serial remote I/O devices are perfect for establishing a cost-effective, dependable, and easy-to-maintain remote process control I/O system. Remote serial I/O products offer process engineers the benefit of simple wiring, as they only require two wires to communicate with the controller and other RS-485 devices while adopting the EIA/TIA RS-485 communication protocol to transmit and receive data at high speed over long distances.
In addition to communication configuration by software or USB and dual RS-485 port design, Moxa’s remote I/O devices eliminate the nightmare of extensive labor associated with the setup and maintenance of data acquisition and automation systems. Moxa also offers different I/O combinations, which provide greater flexibility and are compatible with many different applications.
Easy-to-Use Software Interface for Easy Maintenance
With Moxa’s easy-to-use ioSearch software, you can quickly access all of an ioLogik R1200 device’s status information and settings with a user-friendly graphical user interface. Furthermore, ioSearch also provides an easy method for updating firmware for all ioLogik R1200 devices over an RS-485 network, so you can even update your firmware remotely. The free and easy-to-use ioSearch software reduces the maintenance time and labor required to set up your communication interface. When more than one ioLogik R1200 are on the same RS-485 network, you no longer need to turn hundreds of dials during setup. Instead, simply configure and duplicate each ioLogik R1200’s baudrate and mode through the graphical user interface. This convenient software feature reduces maintenance engineers’ effort, and greatly simplifies upgrading your device’s configuration compared with more traditional methods.
Innovative Hardware Design Reduces Deployment Effort and Enhances Maintenance Efficiency
With the industry’s first RS-485 serial remote I/O with USB design, Moxa provides an innovative solution for upgrading and configuring RS-485 remote I/O communication devices and firmware. All you need to do is upload the configurations to a USB drive, plug it into the field device, and all the configurations and firmware updates will upload to the field device automatically.
Cost-Saving Hardware Design for Backup and Redundancy
Moxa’s ioLogik R1200 Series provides dual RS-485 ports so that when one of your RS-485 ports is damaged, you can quickly switch to the other RS-485 port for quick testing or repair. RS-485 remote I/O devices are already considered a low-cost technology, but with dual RS-485 ports, Moxa helps you save a little bit more. With the ioLogik R1200, you can take advantage of our dual RS-485 ports to set up wiring, provide computer redundancy, or back up your network using two computer topologies. For wiring redundancy, when your computer detects that one of the RS-485 connections is not responding, it can quickly switch over to the other RS-485 line to guarantee continuous communication between field sensors and the central computer. Furthermore, users have the freedom to define the settings. For computer redundancy, the ioLogik R1200 provides system operators with a secure backup when one system goes down.
Additional information
Buttons | |
---|---|
Connector | |
Counter Frequency | |
LED Indicators | |
Baudrate | |
RS-485-2w | |
Industrial Protocols | |
Power Connector | |
No. of Power Inputs | |
Input Voltage | |
Power Consumption | |
Data Bits | |
Flow Control | |
Housing | |
Dimensions | |
Weight | |
Wiring | |
EMC | |
Green Product | |
Time | |
Standards | |
Warranty Period | |
Details | |
Operating Temperature | -10 to 75°C (14 to 167°F) |
Need Support?
We understand that it can be difficult to find the right products for your needs. That’s why our dedicated customer support team is available to assist you in any way possible. Whether you need help selecting the best product for your application or more information on a particular device, our knowledgeable staff is here to provide you with the answers you need. Contact us today for more information about how we can help you get the products and support you need!
Product Brand
ioLogik R1200 Series
L2 managed switch with 8 10/100BaseT(X) M12 Ports, dual power input, 24 to 110 VDC,-40 to 75℃ operating temperature
16 ports Layer 2 Managed Switch with 16 Fast Ethernet ports, 24 to 110 VDC, conformal coating, -40 to 75C operating temperature, IP42.
Industrial Media Converter, multi mode, ST, -40 to 75°C, IECEx Certification Approval
Available on back-order
1 -port RS-232/422/485 wireless device server with 802.11a/b/g /n WLAN, 8DI, 4DO, JP Band
£493.00
Available on back-order
8 ports RS-232/422/485 Terminal server with DB9 connector, Dual 100-200VAC input with adapter with 2 KV isolation
Embedded device server for TTL devices, up to 230.4Kbps, with RJ45, -40 to 85°C
£65.00
1-port RS-232/422/485 serial device server with 2 KV isolation, 10/100MBaseT(X), 1KV serial surge
£342.00
2-port device server, M12 Connector (ethernet, power input), RS-232/422/485 DB9 male, 12~48 VDC, -40~75℃, conformal coating
£1,166.00
Name | Type | Version | Operating System | Release Date | |
---|---|---|---|---|---|
|
Utility |
C63BFA20B8C6ED09EE47AB3C58D3856B6AF0FDA2D72FC232D3A84523778B3D7AD6E6D2AEE7CFCEBD85AC0DE5F714FE03AB0C812319CEB6A58897E2BE034E7AFD SHA-512 |
v2.2 |
Show More
|
Aug 01, 2022 Aug 01, 2022 Release notes |
|
Firmware |
34937E09EBAACA107C6748C50C045BB418AC743B65F7462D1A23E5ED55AAC544963DCE39F1697E0B315068B546C71B968D6B0D07C19813DA678E734F567EDB66 SHA-512 |
v1.2 |
|
Oct 26, 2020 Oct 26, 2020 Release notes |
|
Firmware |
46E958EBFCC4371863B2486A739CB142C93714841A9B5A3BF01F7E49F8A68627A3C6816C1DBFA693C9E7ACCDDD2A1186B32DBADCDA597C2076A29CE64C050849 SHA-512 |
v1.3 |
|
Oct 26, 2020 Oct 26, 2020 Release notes |
|
Firmware |
D9BF714AC99204D5733ABB3225C404575EB98700D73B6AEC042145D4850F19D20048C7EBBFF1190C4CCBC732CC96AD138CE1636F02CE8B7F2FC7EF6B8368B425 SHA-512 |
v1.2 |
|
Oct 26, 2020 Oct 26, 2020 Release notes |
|
Firmware |
A9B9DE091319E278492AF000A8D1BF4819E7A7941F426D35F20A024FD525CA7F16B54473D9C1570605645868FB9D81A75AD274038E07D7BD9705268ECB3408BF SHA-512 |
v1.2 |
|
Oct 26, 2020 Oct 26, 2020 Release notes |
|
Firmware |
33CA8E8FDD74F68779B8CFACE4056CCA63D1765D57784EC6A1C660A015F425B90CAA1BB26BE8B976968B8B290FF1D526956A13482D55A87844A1DC6F319DEE96 SHA-512 |
v1.3 |
|
Oct 26, 2020 Oct 26, 2020 Release notes |
|
Utility |
D1CFF70DCC4A9312A8190FB10C7F541113757E740F429251278FDA3DAF980D72B72E4E2D290B89D53DBC415024FC4540C3F2B4FC2DAC6819004B022735336FE4 SHA-512 |
v1.6 |
Show More
|
Jun 14, 2017 Jun 14, 2017 Release notes |
|
Utility |
C0897104272784DEBB5459E35ED48B836DB1E25A8473EEC938110B2CA0E26E8278C9AFA512D0CDD030652841587F9378EA678C4C89FE2772FEBD54E77D65A693 SHA-512 |
v1.1 |
Show More
|
Jun 14, 2017 Jun 14, 2017 Release notes |
|
Software Package |
8EBF4D548CF6AA1F894EA05AE97024C6AA2A8AB46D3033E093F85048329A81234BF0DE6B3A5C871D95C3165D2B9F3BA16019E368D9854C6E024C48A013BB9E99 SHA-512 |
v1.0 |
|
Jan 10, 2017 Jan 10, 2017 Release notes |
|
Library |
342D1BD752B8A02D1BED1CB3BA1B82DC9422B884C69B8AA32FA119EC8747E839A21495806FA6D84DE9A9E1105FFAD4813257A7B6BD4425A0BB80B9686CEFBE38 SHA-512 |
v2.12 |
|
Dec 27, 2016 Dec 27, 2016 Release notes |
|
Library |
3EF95A861DD1AC313A3280725B3569470471A1647EDC1BA022AE77173F10CA2F885B754301470714EA340BEB6EECFB212486E74110E7E74C5FC1998F257B3D66 SHA-512 |
v1.10 |
Show More
|
Dec 27, 2016 Dec 27, 2016 Release notes |
|
Library |
F16801424DD938ED0320169672E685290663C91EF9E80C6FE827AA6B68C6FB85297E971B2804242646A940F45A7D8A09A572A4D3DDBA3FDF3A500233FF27C5FE SHA-512 |
v2.12 |
|
Dec 27, 2016 Dec 27, 2016 Release notes |
|
Library |
463853F57E87317A2D12F7E4A8104447C66BC34B3B2EA5EF88A9B98302E7F5CB1A43FA3A7BD7F72075BC95CA550CEAC1AB4632B2A188E0C8897694C2FF663E93 SHA-512 |
v2.12 |
Show More
|
Dec 25, 2016 Dec 25, 2016 Release notes |
|
Library |
51DD79A2F63497C273839868C3D3FECB620B607A3D13E6921B925EE9E21C3D116D3BF94C67665645A65DE163770C7D2485930289355E51CDD1BB3AB094D62382 SHA-512 |
v2.11 |
|
Feb 13, 2014 Feb 13, 2014 Release notes |
Show All
Supported Documents
Name | Type | Version | Release Date |
---|---|---|---|
|
QIG | v4.1 |
May 05, 2021 May 05, 2021 |
|
Manual | v3.4 |
Apr 15, 2021 Apr 15, 2021 |
|
Datasheet | v1.0 |
Nov 12, 2018 Nov 12, 2018 |
|
2D CAD | Â | Apr 10, 2014 Apr 10, 2014 |