SDS-3008 Series Multiple Web Vulnerabilities

Published: February 2, 2023

This Alert Is From MOXA

As Industrial IoT (IIoT) adoption continues to proliferate, cybersecurity has become one of the top priorities. The Moxa Product Security Incident Response Team (PSIRT) takes a proactive approach to protect products from cybersecurity vulnerabilities. Moxa PSIRT investigates all reports of vulnerabilities that could potentially affect Moxa products. Moxa created a vulnerability management policy to provide guidance and information to our customers in the event of a reported vulnerability. The management policy ensures that Moxa’s customers have steady, unambiguous resources to help them understand how Moxa resolves or mitigates reported vulnerabilities. For any queries, please email [email protected].

The SDS-3008 Series web server is affected by multiple vulnerabilities. 
–    A remote attacker may disclose unauthorized information or perform a denial-of-service attack.
–    A remote attacker may execute arbitrary script code in the browser of an unsuspecting user.

The identified vulnerability types and potential impacts are shown below:

Item Vulnerability Type Impact
1 Cleartext Transmission of Sensitive Information (CWE-319)
CVE-2022-40693
A cleartext transmission vulnerability exists in the web application functionality of Moxa’s SDS-3008 Series Industrial Ethernet switch v2.1. A specially crafted network sniffing tool can lead to disclosure of sensitive information. An attacker can sniff network traffic to trigger this vulnerability.
2 Insufficient Resource Pool (CWE-410)
CVE-2022-40224
A denial-of-service vulnerability exists in the web server functionality of Moxa’s SDS-3008 Series Industrial Ethernet switch v2.1. A specially crafted HTTP message header can lead to a denial-of-service attack. An attacker can send an HTTP request to trigger this vulnerability.
3 Improper Neutralization of Input During Web Page Generation (CWE-79)
CVE-2022-41311, CVE-2022-41312, CVE-2022-41313
A stored cross-site scripting vulnerability exists in the web application functionality of Moxa’s SDS-3008 Series Industrial Ethernet switch v2.1. A specially crafted HTTP request can lead to arbitrary JavaScript code being executed. An attacker can send an HTTP request to trigger this vulnerability.
4 Information Exposure (CWE-200)
CVE-2022-40691
An information disclosure vulnerability exists in the web application functionality of Moxa’s SDS-3008 Series Industrial Ethernet switch v2.1. A specially crafted HTTP request can lead to disclosure of sensitive information. An attacker can send an HTTP request to trigger this vulnerability.

 

This alert has come from: https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities