EDS-405A Series

Entry-level managed Ethernet switch with 5 10/100BaseT(X) ports, -40 to 75°C operating temperature

Description

Layer 2 Managed Switches

Moxa’s Layer 2 managed switches feature industrial-grade reliability, network redundancy, and security features based on the IEC 62443 standard. We offer toughened, industry-specific products with multiple industry certifications, such as parts of the EN 50155 standard for rail applications, IEC 61850-3 for power automation systems, and NEMA TS2 for intelligent transportation systems.

Ethernet Interface

  • 10/100BaseT(X) Ports (RJ45 connector)

    5
    Auto negotiation speed
    Full/Half duplex mode
    Auto MDI/MDI-X connection

  • Optical Fiber

    Read more

  • Standards

    IEEE 802.3 for 10BaseT
    IEEE 802.3u for 100BaseT(X) and 100BaseFX
    IEEE 802.3x for flow control
    IEEE 802.1D-2004 for Spanning Tree Protocol
    IEEE 802.1p for Class of Service
    IEEE 802.1Q for VLAN Tagging
    IEEE 802.1w for Rapid Spanning Tree Protocol

Ethernet Software Features

  • Filter

    802.1Q VLAN, GMRP, GVRP, IGMP v1/v2, Port-based VLAN

  • Industrial Protocols

    EtherNet/IP
    Modbus TCP

  • Management

    Back Pressure Flow Control, BOOTP, DHCP Option 66/67/82, DHCP Server/Client, Flow control, IPv4/IPv6, LLDP, Port Mirror, RARP, RMON, SMTP, SNMP Inform, SNMPv1/v2c/v3, Syslog, Telnet, TFTP

  • MIB

    Bridge MIB, Ethernet-like MIB, MIB-II, P-BRIDGE MIB, RMON MIB Groups 1, 2, 3, 9, RSTP MIB

  • Redundancy Protocols

    RSTP, STP, Turbo Chain, Turbo Ring v1/v2

  • Time Management

    NTP Server/Client
    SNTP

Switch Properties

  • IGMP Groups

    256

  • MAC Table Size

    2 K

  • Max. No. of VLANs

    64

  • Packet Buffer Size

    1 Mbits

  • Priority Queues

    4

  • VLAN ID Range

    VID 1 to 4094

Serial Interface

  • Console Port

    RS-232 (TxD, RxD, GND), 10-pin RJ45 (19200, n, 8, 1)

DIP Switch Configuration

  • Ethernet Interface

    Turbo Ring, Master, Coupler, Reserve

Input/Output Interface

  • Alarm Contact Channels

    Relay output with current carrying capacity of 1 A @ 24 VDC

Power Parameters

  • Input Voltage

    12/24/48 VDC, Redundant dual inputs

  • Operating Voltage

    9.6 to 60 VDC

  • Input Current

    0.21 A @ 24 VDC

  • Overload Current Protection

    Supported

  • Reverse Polarity Protection

    Supported

  • Connection

    1 removable 6-contact terminal block(s)

Physical Characteristics

  • Housing

    Metal

  • IP Rating

    IP30

  • Dimensions

    53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in)

  • Weight

    650 g (1.44 lb)

  • Installation

    DIN-rail mounting, Wall mounting (with optional kit)

Environmental Limits

  • Operating Temperature

    -40 to 75°C (-40 to 167°F)

  • Storage Temperature (package included)

    -40 to 85°C (-40 to 185°F)

  • Ambient Relative Humidity

    5 to 95% (non-condensing)

Standards and Certifications

  • Safety

    UL 508
    UL 60950-1

  • EMC

    EN 55032/24

  • EMI

    CISPR 32, FCC Part 15B Class A

  • EMS

    IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
    IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
    IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
    IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
    IEC 61000-4-6 CS: 10 V
    IEC 61000-4-8 PFMF

  • Hazardous Locations

    ATEX
    Class I Division 2

  • Maritime

    DNV-GL

  • Traffic Control

    NEMA TS2

  • Freefall

    IEC 60068-2-31

  • Shock

    IEC 60068-2-27

  • Vibration

    IEC 60068-2-6

MTBF

  • Time

    1,547,941 hrs

  • Standards

    Telcordia (Bellcore), GB

Warranty

  • Warranty Period

    5 years

  • Details