MGate 4101-MB-PBS Series
Protocol conversion between Modbus and PROFIBUS
Supports PROFIBUS DP V0 slave
Supports Modbus RTU/ASCII master and slave
Windows utilities with innovative QuickLink function for automatic configuration within minutes
Status monitoring and fault protection for easy maintenance
Embedded traffic monitoring/diagnostic information for easy troubleshooting
Supports redundant dual DC power inputs and 1 relay output
-40 to 75°C wide operating temperature models available
Serial port with 2 kV isolation protection (for “-I” models)
Introduction
The MGate 4101-MB-PBS gateway provides a communication portal between PROFIBUS PLCs (e.g., Siemens S7-400 and S7-300 PLCs) and Modbus devices. With the QuickLink feature, I/O mapping can be accomplished within a matter of minutes. All models are protected with a rugged metallic casing, are DIN-rail mountable, and offer optional built-in optical isolation.
QuickLink and Windows Utilities for Easy Setup and Traffic Monitoring
The QuickLink windows utility uses a serial console port to connect to the MGate 4101-MB-PBS and makes configuration and operation as easy as possible. QuickLink can finish the configuration in just a few minutes by passively detecting Modbus requests with the AutoLearning function, and performs error-free I/O mapping with the AutoMapping feature. QuickLink drastically reduces Modbus-to-PROFIBUS integration time when compared to conventional I/O mapping, which can easily require days to complete. Additionally, embedded monitoring tools can maintain logs of Modbus communication packets and assist in troubleshooting.
Redundant Power Inputs
The MGate 4101-MB-PBS has dual power inputs for greater reliability. The power inputs allow simultaneous connection to 2 live DC power sources, so that continuous operation is provided even if one power source fails. The higher level of reliability makes these advanced Modbus-to-PROFIBUS gateways ideal for demanding industrial applications.
Warning by Relay Output
A relay output is provided for the power input status. The relay output gives maintenance engineers an additional tool for troubleshooting and maintenance.
PRODUCTS IN THIS SERIES
1-port Modbus to PROFIBUS Slave gateway with 2KV Isolation, 12-48VDC, -40~75°C
£746.00
Available on back-order
1-port Modbus to PROFIBUS Slave gateway with 2KV Isolation, 12-48VDC, 0~60°C
£618.00
Other Series
Name | Type | Version | Operating System | Release Date | |
---|---|---|---|---|---|
|
Utility |
39E6FCCC3F900BB036A9693910A306ADC26FAC5B3F8BCE83EE8177FCDC7F306ADAECCC5BA751641BFDD61956C0E4D72B6634D1C3F662362EE658CBB3F2EB8170 SHA-512
|
v1.17 |
Show More
|
Apr 29, 2022 Apr 29, 2022 Release notes |
|
Firmware |
DFBED81669ABF057E2B75450050CFA1427F39B41FDBF8CC2F1A3F074FAD227721FCF715F21453ADB5AEA31D070C8FC2F947F2CEF0F0BD9E90DC853FB1F6A8B8B SHA-512
|
v2.0 |
|
Apr 22, 2020 Apr 22, 2020 Release notes |
|
Software Package |
8F574396428FA9021EAB0784A50551184B8A21A9FF463700C8E653794DCB5DBE4481DEB6B2D1D19164531AA5A0C9258983710961EE20B6E73D3B8CA279CDBC32 SHA-512
|
v1.0 |
|
Mar 15, 2012 Mar 15, 2012 Release notes |
Show All
Supported Documents
Name | Type | Version | Release Date |
---|---|---|---|
|
Manual | v6.1 |
Apr 25, 2022 Apr 25, 2022 |
|
QIG | v6.1 |
Apr 23, 2021 Apr 23, 2021 |
|
Datasheet | v1.0 |
Nov 12, 2018 Nov 12, 2018 |
|
Tech Note | v1.0 |
Jul 19, 2017 Jul 19, 2017 |
|
Tech Note | v1.0 |
Jan 06, 2015 Jan 06, 2015 |
|
Tech Note | v1.0 |
Jan 06, 2015 Jan 06, 2015 |
|
2D CAD | Oct 06, 2014 Oct 06, 2014 |
|
|
2D CAD | Oct 06, 2014 Oct 06, 2014 |
Show All